DMRG Rules 80Chapter X · Power Supply and Traction Arrangements
Section 80 · Procedure for preventing admission of electric rolling stock into or over sections of tract with dead or earthed overhead lines
Text size — level 1 of 4
(1)
In order to prevent electric rolling-stock from being admitted into a track or a crossover for which overhead equipment is made dead or for which a permit-to-work is to be issued, the levers or slide or push buttons, etc., of signals and points governing movement of electric rolling Stock shall be suitable protected and if the points and.signals are locally operated they shall be clamped and padlocked in their normal position and the keys shall be kept with the Station Controller.(2)
These protective measures shall not be withdrawn until the Station Controller receives a message from the Traffic Controller and acknowledges the same, and the Traffic Controller shall not issue such a message unless he has received a message from the Traction Power Controller cancelling the Power Block.Your private note on this section